S5
For Windows
|
- Simatic
PLC Programming Under Windows.
- Professional
PLC Programming and Program Testing
with The integrated Simulation PLC.
- IBH
softec "S5 & S7 for Windows"
- Graphical
Step Sequence Programming
|
- Ascil
Import and Export
- Built
In DDE Server
- Real
Time PLC
- DLL
Tool Kit
- Eprommer
|
|
|
Technical
Requirements and Specifications
1.
System Requirements
Windows compatible Personal Computer, to run Microsoft
Windows 3.1x (386 SX or better, minimum 4 MB RAM), Windows
95/NT (486,or Pentium 16 MB RAM). 6MB disk space. Floppy
Disk drive 1,44MB/ 3,5 inch.
|
|
2.
Instruction Set
S5 for Windows supports the complete set of SIEMENS
STEP5 Instructions.
S7 for Windows supports the SIEMENS
STEP5 instruction minus the instructions not
supported by S7. In addition, the System Function (SFC)
are supported.
|
|
3.
File Format
S5 for Windows: Internal file format with the date the
Block was Created / change date and a Block comment.
Import and Export of SIEMENS PLC
programs with comments and extended comments.Symbolic
files in the SEQ. format.
A Shareware program to convert CPM disks in both directions
is available. S7 for Windows:
Internal file Format with the date the Block was created
/ change date and a Block comment. STL format for PLC
program export.
|
|
4.
Presentation
Block List with the date of the last modification of
each Block. Control System Flowchart (CSF),
Statement List (STL). Ladder
Logic (LAD) and Graphical
Step Sequence (G5 for Windows)
programming.
|
5.
Editing
Ladder Logic (LAD), Control
Flowchart (CSF), and step
Sequence (G5 for Windows)
programming with graphic editor using mouse or key Board.
Statement List, Symbolic Table and extended com comment
with integrated text editor. Cut, Copy and Paste function
via the Windows Clipboard. This function can move text
to other Window applications.The Symbolic Table editor
is integrated with the Ladder Logic (LAD),Control
System Flowchart (CSF), statement
List (STL), and Step Sequence
display. |
6.
Cross Reference
On-line Cross Reference with a mouse or keyboard for a
selected Address (symbolic or absolute) from the edit
or status windows. Direct Jump to the block from the Cross
Reference list. Double use supported (if a word or byte
and a bit from the same address is used separately).Cross
Reference printout. |
7.
Symbolic Table
Editing with the integrated or external editor. Check
if address (symbolic or absolute) is defined more than
once. Sorting by addressor symbol. Search and display
of undefined addresses. Rewire (search and replace). |
8.
Block Functions
Blocks (single or groups) may be selected (marked) with
the mouse or the keyboard. These blocks may then be transmitted
from / to the PLC, renamed, copied, or copied into other
programs. |
9.
Online Functions
Block Status display in Ladder Logic (LAD),
Control System Flowchart (CSF),
Statement List (STL) or STEP
Sequence programming. Signal Set and Reset directly within
the status display. PLC Blocks List, Compress PLC Memory,
Block comparison with the PLC, and Interrupt Stack Display
with the part of a faulty program. Display and modifyVariables
directly within the status display. |
10.
Printing
Block List with the date of Block creation or change and
comments.Blocks in ladder Logic (LAD),
Control System Flowchart (CSF),
statementList (STL), or Step
Sequence programming. Cross Reference, Symbolic
Table, Footer with file name, Block name, Block creation
or change date, Programmer name, date printed, three (3)
lines for company name and address, two (2) lines for
special use (unassigned) Sheet number. Fonts
and sizes selectable. Support for all printers selected
under Windows. |
11.
Help Function
Help with index. Help for selected function. |
|
12.
Simulation PLC
Step
5 instructions up to the SIEMENS
SIMATIC PLC 115U (CPU 944) without systems commands.
PLC memory only limited by the PC Main memory. 1024
Inputs and 1024 outputs. 128 Peripheral Bytes.
2048 Flags. 128 Timer and 128 Counters. 256 of each
OB, PB, FB, FX, DB,DX, SB.
Block Status presentation in Function Logic, Ladder
Logic, Statement List or Step Sequence programming.
Signal Set and Reset directly Within the status display.
Single step program execution down to Single instruction
lines. Transfer of peripheral bytes to and from Hardware
ports (addresses). Call customer defined DLL's DDE -
Interface.
|
|
13.
Extended Simulation PLC
Step 5 instructions of the SIMATIC
PLC 115U 945 with all systems
Commands and identical memory allocation. 720 Kbyte
PLC memory.
1024 Inputs and 1024 Outputs. 128 Peripheral bytes.
2028 Flags. 128 Timer and 128 Counters. 256 of each
OB,PB,FB,DB,DX,SB. Block status presentation in Function
Logic, Ladder Logic, Statement List or Step Sequence
programming. Signal Set and Reset directly within the
status display. DDE - Interface.
|
|
|
The
S5 for Windows® is an excellent software tool for creating,
modifying, testing, and documenting programs for Programmable
Logic Controllers (PLC). S5 for Windows® is used to program
the Siemens PLC family SIMATIC® S5 with the programming
language STEP® 5. The logic presentation is available
in Ladder Diagram (LAD), Control System Flowchart (CSF), Statement
List (STL), and Graphical Step Sequence (G5 for Windows®)
for programming, editing, and testing. Import and Export Functions
are available to convert existing programs in the S5 for Windows®
format and vice-versa.
Creating
and Editing
The
Editor, integrated under S5 for Windows®, can create,
modify, and manage the contents of an entire Symbol Library,
as well as search and replace functions with multiple criteria.
This Editor provides the same easy to use tools as supplied
with other Windows applications. The function "Rewire"
is extremely easy to use. A Syntax check for existing addresses,
absolute or symbolic is also integrated.
The Editor, when used to create Ladder Diagrams or Control
System Flowchart, can display complex functions. Special care
has been taken to allow easy operations with the Mouse and
/ or the Keyboard. A Cross Reference List and / or the corresponding
Symbol Library with the correct address is displayed simultaneously.
The Symbol Library may be edited in its own window simultaneously.
The allocation of new addresses with a syntax check is integrated.
Statement Lists may be created with the same easy to use tools
of the Symbol Editor. The Windows Clipboard with the Cut-,
Copy-, and Paste Functions is supported for easy Statement
List manipulation. Statement Lists may be converted to Ladder
Diagrams or Control System Flowchart, if they can be displayed.
Converting Ladder Diagrams or Control System Flowchart into
Statement Lists is always possible.
Documentation
S5 for Windows® supports the installed Windows Printer.
The program created will be printed with multiple comments
and preset headers and footers. The selection of font and
size are obvious. A separate dialog box is provided to select
groups of operands to be printed as a Cross Reference list.
Open windows, such as the status window, may also be printed.
|
| |
| |
For
more information on S5/S7 for Windows
and how iTech can meet
your automation needs, send us an email
now.
|
| |
|
|
|
|
|